• Home
  • About Us
  • Rep List
  • Options
  • Contact Us
  • Products
  • Sizing
  • ES-MBA Parts
  • Installation Manuals
  •  
  • HVAC
  • Direct Steam Heating
  • Humidification
  • Vessel Heating
  • Hot Water for Process
    & Comfort Heating
  • Distillation, Sterilization
    & Autoclave Use
  • Clean Steam: Pharmaceuticals,
    Cosmetics & Food Processes
  • Processing Waxes.
    Paraffin & Glues
  • Heat Pump Auxiliary
    Heating
  • Anti-freeze Protection,
    Preheating & Fuel Oil Lines
  • Bakery Overs, Proofers
  • Jacketed Reactors
  • In-line Steam Superheating
  • Microbreweries
  • On-site Power Plant
    & Utility Steam
  • Air, Water, Oil Preheating
    and Booster Heating
  • Environmental Rooms,
    Test Chambers and Ovens
  • Laboratory/Experiment
    Environments
  • Steam for
    Jacketed Kettles
  • Food Manufacturing
     
  • SVW IOM
  • MBA IOM
  • ES/SSB/HU IOM
  • SVS IOM
  • ES24A IOM
  • ES30A/ES36A
Print Page

SSB Electric Steam Boilers: Specifications

BOILER
MODEL
KW
BHP
LBS.
STEAM
/HR.##
3 PHASE
VOLTAGE
#
TOTAL
AMPERAGE
INCHES
W L H
SHIP
WT.
SSB-12*
12
1.22
36.2
208
240
480
34
29
15
20 28 36
260
SSB-18*
18
1.84
54.2
208
240
480
50
44
22
20 28 36
270
SSB-24*
24
2.45
72.3
208
240
480
67
58
29
27 33 45
330
SSB-30*
30
3.06
90.4
208
240
480
84
73
37
27 33 45
340
SSB-36*
36
3.67
108
208
240
480
100
87
44
27 33 45
350
SSB-48
48
4.89
145
208
240
480
128
111
56
27 33 45
365
SSB-60
60
6.12
181
208
240
480
167
145
73
27 33 45
410
SSB-72
72
7.35
217
208
240
480
200
174
87
27 33 45
420
SSB-100
108
11.0
325
208
240
480
284
246
123
28 34 59
675
SSB-135
144
14.6
433
208
240
480
400
347
173
30 36 61
785
SSB-160
158
161
475
240
480
379
190
30 36 61
785
SSB-180
180
18.4
542
240
480
434
217
30 36 61
790



*Single phase available.
#Other voltages available.
##With 50° feedwater.

NOTE:

  • All wetted metal parts are stainless stell. Consult Factory for specific wetted parts materials.
  • Allow 21 inches for heating element removal When ordering: specify model number, KW, volts, phase and optional equipment.
  • Minimum of 1 meg ohm-cm specific resistivity feed water must be used for proper & safe boiler operation.

<<Return to SSB Main Page>>