Sussman SVS Electric Boilers are safe, versatile
easy to-use heat sources for low or high pressure steam. Applications
include steam for:
- CHEMICAL TANKS
- REACTORS, DISTILLATIONS & AUTOCLAVES
- DYESTUFFS
- FOOD PROCESSING
- JACKETED VESSELS FOR PROCESSES
- PIPE TRACING
- VISCOUS MATERIAL
- FUEL OIL LINE HEATING
- ANTIFREEZE PROTECTION
- COMFORT HEATING & HUMIDIFICATION
ENGINEERED FOR:
- EASY INSTALLATION
- AUTOMATIC OPERATION
- CLEAN, FUME-FREE, QUIET RELIABLE STEAM AT
THE TURN OF A SWITCH
- ALTERNATE SOURCE OF STEAM WHEN MAIN BOILER
IS NOT IN USE
- NO ON-SITE FUEL COMBUSTION
- LOW MAINTENANCE
- NO FUEL DELIVERY/STORAGE PROBLEMS
- FACTORY TESTED - READY TO OPERATE
|
|
SVS STANDARD FEATURES:
- INSULATED
ASME CODED AND STAMPED STEEL, PRESSURE VESSEL
CODE S, SECT. I, 150PSIG
- BUILT
TO UL, NATIONAL BOARD REQUIREMENTS
- STANDARD
150PSIG DESIGN - HIGHER PRESSURE AVAILABLE
- FULLY
INSULATED VESSEL, 2" THICK INSULATION
- ASME
CODE SAFETY VALVE
- NPT
INLET/OUTLET FITTINGS UP TO 3 1/2", FLANGED
INLET/OUTLET FITTINGS FOR 4" AND OVER.
(SEE SPECIFICATION CHART)
- VERTICALLY MOUNTED INCOLOY
SHEATHED IMMERSION ELEMENTS COMPLETE WITH
EPOXY END SEAL
- NEMA 1, EPOXY FINISHED GASKETED/LOUVERED
CONTROL PANEL AND HEATER ENCLOSURE
- BLOWDOWN/DRAIN VALVE
- PRESSURE GAUGE WITH ISOLATING
STOPCOCK
- LIQUID LEVEL GAUGE GLASS
ASSEMBLY
- BACKFLOW CHECK VALVE AND
SOLENOID FEEDWATER VALVE
- STANDARD PRESSURE RANGE 20-150
PSIG (HIGHER PRESSURES MAY BE AVAILABLE UPON
REQUEST)
- MODULATING PRESSURE CONTROL
(STANDARD OVER 90A)
- ELECTRONIC FEEDWATER CONTROL
- BOILER OPERATING MODE INDICATOR
LIGHTS
- SUB-DIVIDED CIRCUIT FUSING,
CLASS "J", HRC FORM 1
- INDUSTRIAL RATED AMGNETIC
CONTACTORS
- MANUAL RESET HIGH LIMIT PRESSURE
CONTROL
- MAIN & AUXILIARY LOW
WATER CUT OFF CONTROLS
- 120V CONTROL CIRCUIT C/W
ON/OFF SWITCH AND INDICATING PILOT LIGHT
- 120VAC CONTROL CIRUIT TRANSFORMER
WITH PRIMARY & SECONDARY FUSING
SVS
OPTIONAL EQUIPMENT:
- STEAM
OUTLET GLOBE VALVE (150 PSIG)
- TIMED
AUTOMATIC BLOWDOWN SYSTEMS
- AUXILIARY
LOW WATER CUTOFF
- MANUAL
RESET LOW WATER CUTOFF
- AUXILIARY
HIGH PRESSURE CUTOFF, FOR AUTO OR MANUAL RESET
- HIGH
PRESSURE ALARM
- LOW
PRESSURE ALARM
- AUDIBLE
ALARM WITH SILENCER
- PILOT
LIGHT FOR EACH HEATING STAGE
- MANUAL
OFF/AUTO SWITCH FOR EACH HEATING STAGE
- VOLTMETER,
COMPLETE WITH 3 POSITION SELECTOR
- WATTMETER
- AMMETER
W/3 POSITION SELECTOR
- UNFUSED
DISCONNECT SWITCH
- SAFETY
DOOR INTERLOCK SWITCH
- MOTOR
STARTER WITH OVERLOADS
- FLANGED
INLET/OUTLET
- VACUUM
BREAKER
- kW-HR
METER
- GROUND
FAULT INDICATOR
<<View SVS Spec. Sheet>>
View SVS Brochure |